TELECOM POWER SOLUTIONS

Rack Power for Telecom Sites — Rectifiers, Inverters and DC-DC Conversion

48V DC rectifier systems, rack-mounted inverters and DC-DC converters for telecom cabinets, base stations and backup power rooms. VOITA supplies operators, system integrators and distributors — with the rectifier, the inverter and the rack mechanics specified against one site requirement.

48V DC Systems
Rectifier & Inverter
19-Inch Rack Mount
OEM / ODM Programs
Telecom Power Solutions
WHO WE SERVE

One Power Supplier Across the Site Build

A telecom power rack has three different buyers behind it — the operator who has to keep the site on air, the integrator who has to fit it into a cabinet that already exists, and the distributor who has to support it years later. All three need the same thing: it has to fit, and it has to stay up.

Telecom Operators & Site Builders

Power equipment for base stations, cabinets and backup rooms, specified against the load and the battery string the site actually runs.

System Integrators & EPC

Rack-mounted equipment for projects where the cabinet height, the DC bus and the AC load are fixed before the power equipment is chosen.

Distributors & Service Networks

Stock and replacement supply across rectifier, inverter and converter functions, with documentation for your market and your service teams.

POWER ARCHITECTURES

48V DC, 220V AC and the Conversion Between Them

48V DC is the common language of telecom sites, but it is not the whole specification. The current, the redundancy, the battery string and the AC load behind the inverter are what decide whether the rack performs. Those are the numbers we set with you.

48V DC Rectifier Systems

AC to 48V DC conversion with battery charging, sized for the site load plus the recharge current the string needs.

48VDC to 220VAC Inverters

Rack inverters that supply AC loads from the DC bus, from a compact unit up to 8kVA and 10kVA high-frequency models.

48VDC to 220VDC Converters

DC-to-DC conversion between bus levels inside the cabinet, for equipment that does not run on the site’s primary DC voltage.

Choosing the right architecture

FunctionTypical applicationWhat we configure
Rectifier systemConverting AC site power to a 48V DC bus and charging the battery stringOutput current, module count and redundancy matched to the site load
Rack inverterSupplying 220V AC loads from the 48V DC busOutput rating and transfer behaviour set against the AC load and the battery
Rack DC-DC converterConverting between DC levels inside the cabinetInput and output levels matched to the existing bus and the equipment being fed
CustomNon-standard voltages and OEM requirementsDeveloped with you against the site specification
RECTIFIER SYSTEMS

48V DC Is Only the Starting Point

A rectifier system does three jobs at once — it converts, it charges, and it carries the site load while the battery is doing neither. Sizing it on the load alone is the usual reason a site browns out during a long outage.

Telecom power supply rectifier and inverter system
VOITA rack-mount telecom power inverter with AC input and output, PV input, parallel connection ports and circuit breakers
RACK & INSTALLATION

The Rack Has a Height, a Depth and a Cable Route

Telecom power equipment lives in a cabinet that already has a height, a depth and a cable route. We work from the rack side of the installation — the available units, the mounting rails and the termination points — and configure the equipment to it.

TELECOM RANGE

Rack-Mounted Power for 19-Inch Cabinets

From a 2.4kW rectifier module to a 19-inch 3U 200A rectifier system, the range covers the DC power, inversion and conversion stages of a telecom site.

VOITA white background power supply

Rectifier Systems

AC to 48V DC rectification with battery charging, sized for the site load plus the recharge current the string needs.
VOITA white background power supply

Rack Inverters

Rack inverters that supply 220V AC loads from the 48V DC bus, in compact, 5kVA, 8kVA and 10kVA formats.
VOITA white background power supply

Rack DC-DC Converters

48VDC to 220VDC conversion inside the cabinet, for equipment that does not run on the site’s primary DC voltage.
BATTERY & BACKUP

The Rectifier Charges a Battery Bank You Already Own

A rectifier only works as well as the battery string behind it. Float and boost behaviour, low-voltage disconnect and the transfer to inverter have to agree with the battery the site already has, or the backup does not behave as designed.

Telecom Power Solutions
HOW WE SUPPLY

Three Ways to Buy Telecom Power

A new site build and a failed rectifier in an existing cabinet have almost nothing in common. We handle both, with the same technical file behind them.

Project Supply

Equipment supplied against a site build or rollout programme, with consistent configuration and documentation across every rack delivered.

OEM & Custom Branding

Your branding, labelling and documentation on the unit that reaches the site, with the configuration fixed to your specification.

Replacement & Spares

Matching supply for racks already in service. Send the existing model, the DC bus voltage and the current rating and we propose the replacement.

Telecom Power Solutions
VOITA telecom inverter and rectifier range for 19-inch rack installations
QUALITY & DELIVERY

From Site Requirement to a Commissioned Rack

VOITA works with qualified manufacturing resources to support PCB assembly, product assembly, wiring, testing and customized production, coordinated under VOITA-defined technical, quality and delivery requirements.

01

Requirement & Matching

Site load, DC voltage and current, the battery string in service and the rack space available are reviewed and turned into a power specification.
02

Sample & Validation

Samples are produced against the agreed configuration and validated before a production release.
03

Production & QC

Assembly, wiring and testing are carried out under VOITA-defined technical, quality and delivery requirements.
04

Delivery & After-Sales

Packing, documentation and shipping are coordinated with your schedule, with after-sales support.

Send us your site requirement

Tell us the site load, the DC voltage and current, the rack space available and how many units you need — we will come back with a configuration and a quotation.

FAQ

Questions Telecom Buyers Ask Us

Our telecom range is built around a 48V DC bus, which is the standard for the sites these systems are specified into. Systems rated at 2.4kW and at 150A and 200A in 19-inch rack formats are part of the range, with the configuration matched to your load.

Yes. Rectifier systems, rack inverters and rack DC-DC converters are all supplied from the same range, so the DC power stage, the AC loads and any intermediate DC levels can be specified against one site requirement instead of being matched afterwards.

The output has to cover the site load and still have capacity to recharge the battery. Send us the load, the battery capacity and the recharge time you expect, and we will propose the module count and redundancy that fits.

Yes. 19-inch rack mounting is the standard format across the telecom range, including 3U rectifier systems and 2U rack equipment. Tell us the rack units available and we will confirm the configuration that fits the cabinet.

The rack inverter range covers 220V AC output from a 48V DC bus, in pure sine wave and high-frequency designs, with models rated at 5kVA, 8kVA and 10kVA. The rating is chosen against the AC load the site needs to carry.

Yes. Replacement and spares supply is part of our telecom business. Send the existing model, the DC bus voltage and the current or power rating, and we will propose a matching replacement.

Tell Us About Your Telecom Project

Share the site load, DC voltage, rack space and volume — our team normally responds within one business day.

Scroll to Top
Contact VoitaTech sales team for inquiry

Tell Us About Your Project

Share your application and expected quantity — our B2B team will recommend a suitable platform or custom build.

Get a quote

Contact VoitaTech sales team for inquiry

Let's have a chat

Get a tailored quotation

Contact Information