One Enclosure, Two Current Ratings: A 40 A / 60 A DC-DC Project for a Middle East Vehicle and Storage Supplier

A vehicle and storage supplier in the Middle East wanted two DC-DC ratings — 40 A and 60 A — to come out of one housing. On paper that is a cost request. In practice it is a thermal one.

The reason for asking was commercial: separate housings mean separate tooling, separate cartons and two stock lines to plan. The condition attached to it was absolute: the 60 A version could not leave the shared housing with less cooling headroom than it had before.

40A and 60A vehicle-mounted DC-DC converters sharing one enclosure
One enclosure, two ratings. The 60 A version keeps its own heatsink module and the same fan, so nothing in the thermal path was traded for the shared box.

The application: two ratings, one stock line

Two ratings, one stock line. Both units serve the same market and often the same customer — the 40 A version on lighter builds, the 60 A version where the load is heavier. They are ordered together, stocked together and shipped together. Two housings would have meant two of everything behind that sentence.

The environment removes the slack. This is not a temperate market. Air around the unit is already warm before any load is applied, so the thermal design has less room to give than a comfortable test bench suggests. Whatever the enclosure does to airflow, it does it every day of the year, at the worst hour of the day.

What sharing a housing really touches. Tooling, cartons, labels, inspection paperwork and stock lines all collapse into one set. The heatsink does not. That is precisely where a shared-enclosure project either works or quietly gives away the margin it was supposed to protect.

The constraint

Three things had to be true at the same time, and the cheapest answer to any one of them broke another.

1. One housing. A single tool, a single carton specification, a single stock line. If the 60 A version needed a different box, the whole request disappeared.

2. The 60 A keeps its thermal margin. The housing must not become the limiting component. A shared box that runs the 60 A hotter than a dedicated one is not a saving; it is a warranty claim with a delivery date.

3. The fan must not run permanently. A fan is a wear item and a dust pump. Running it from switch-on spends its rated life on hours when there is nothing to cool, and leaves no extra headroom for the hours that matter.

The trap is that the easy way to share a housing is to share everything inside it — one heatsink, one airflow path — which is exactly how the 60 A loses its margin. The easy way to protect the 60 A is to give it a bigger box, which throws away the reason for the project.

Our call: the fan threshold

The specification we were handed set the fan to start at one fixed temperature. That number suits a temperate duty cycle. In this market the air around the unit can sit close to it with no load applied at all, so the fan would have been running almost continuously: rated life spent during the cool hours, and nothing held back for the peaks.

We proposed a start point above the stop point rather than one shared number. That gap is a dead band, and it does two jobs. It stops the fan cycling on and off around a single threshold, which is what wears a bearing out fastest. And it moves the start point clear of the ambient the unit actually lives in, so the fan is reserved for heat the unit produced itself.

That is the one place where this project departed from the brief. Everything else was built to what was asked.

What we built

The shared part is the enclosure, and only the enclosure. Inside it, the 60 A version keeps its own heatsink module and the same fan it would have had in a dedicated box, so the thermal path is unchanged from the design that was already proven.

ItemSpecification
Ratings40 A and 60 A from one enclosure
Shared between ratingsHousing, mounting pattern, carton, labels
Not sharedHeatsink module — the 60 A keeps its own
FanDual ball bearing, 8,000 rpm ± 10%
Fan static pressure3.86 mmH₂O
Fan rated life50,000 h at 40 °C
Fan controlThermally triggered; start point set above the stop point
PackagingOne carton holds both ratings; rating checkbox plus SKU and serial fields on the box

The last row is not an afterthought. With two ratings in one carton, the box itself has to say which unit is inside before anyone opens it — hence the printed checkbox and the SKU and serial fields, filled at packing rather than on a separate label.

Why the fan runs on its own heat

Unit temperatureFanReason
Below the start pointOffNo heat to move; ambient alone does not start it
Between stop and startStill offDead band — the fan waits for the start point, not the stop point
At the start pointStartsHeat generated by the unit, not by the weather
Back down to the stop pointStopsHysteresis prevents short cycling

A single threshold looks simpler and behaves worse. Put start and stop on the same number and the fan hunts around it: on, off, on, off, all afternoon, every time the temperature crosses the line. Bearings do not fail from steady running nearly as fast as they fail from that.

The 50,000 h figure is a rating at 40 °C, not a promise at any temperature. In a hot market the honest question is not "how long does the fan last" but "how many hours a day is it asked to run". Moving the start point is what changed that number, not a different fan.

What we did not do

We did not put both ratings on one heatsink. It would have made the inside of the unit as identical as the outside, and it is the single fastest way to lose the 60 A margin while appearing to save money.

We did not keep the single start point. Building to the number as written would have produced a unit that passes a bench test and runs its fan to death in the field. The start point is the one item we argued with.

We did not add a second enclosure for the 60 A. It would have solved the thermal question by deleting the commercial one — back to two tools, two cartons and two stock lines.

Result

One housing, two ratings, and a fan that runs only when the unit has heat of its own to move.

The supplier now plans one tooling set, one carton specification and one stock line, with the rating marked on the box. The 60 A version keeps the heatsink and the airflow it was designed around, so nothing in its thermal path was traded for the shared enclosure. On a normal day the fan stays off until the unit earns it.

If you are specifying something similar

Four things decide whether two ratings can share a housing without one of them losing margin:

  • The maximum ambient at the unit, not the city on the weather map. A box in direct sun beside a warm bulkhead lives in a different climate from the forecast.
  • Continuous or intermittent duty. A 60 A unit that holds its rating for hours needs a different heatsink from one that reaches it in bursts.
  • The airflow path after installation. The best fan in the enclosure is wasted if the unit is bolted into a closed compartment with no way in or out.
  • What the fan is allowed to start at, and where it should stop. Give us the ambient range and we will tell you whether the threshold in your draft is a control point or a permanent-on switch.

Every converter we ship carries a 2-year warranty. If you are planning two ratings from one housing, send us the ambient range, the duty cycle and where the unit will sit. We will tell you which parts can be shared, which cannot, and what that does to the thermal margin before any tooling is cut.

See the DC-DC converter range →

Share:

More Posts

Related Solutions

Send Us A Message

Scroll to Top
Contact VoitaTech sales team for inquiry

Tell Us About Your Project

Share your application and expected quantity — our B2B team will recommend a suitable platform or custom build.

Tell us three specs - we will name the model

Contact VoitaTech sales team for inquiry

Let's have a chat

Get a tailored quotation

Contact Information